Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Type of study
Language
Year range
1.
Indian J Ophthalmol ; 2015 May; 63(5): 459-462
Article in English | IMSEAR | ID: sea-170370

ABSTRACT

ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medications) was achieved in eight cases (66.7%) and qualified success (IOP ≤ 18 mmHg, with additional glaucoma medications) in two cases (16.7%) at 1‑year after surgery. Early intervention was needed in 4 patients; two underwent anterior chamber reformation while the other two required needling. Two patients required resurgery. There was no significant change in the best corrected visual acuity postoperatively (P = 0.37). ExPress GFD does not seem to offer a benefit over standard trabeculectomy in patients with advanced glaucomatous disease in terms of IOP control or complication rate. However, due to the small sample size with a heterogeneous mixture of primary and secondary glaucoma’s, we await further studies with a larger sample size and long‑term follow‑up, to see how the device performs.

2.
Indian J Ophthalmol ; 2014 Nov ; 62 (11): 1045-1055
Article in English | IMSEAR | ID: sea-155790

ABSTRACT

Glaucoma is an acquired progressive optic neuropathy which is characterized by changes in the optic nerve head and retinal nerve fiber layer (RNFL). White‑on‑white perimetry is the gold standard for the diagnosis of glaucoma. However, it can detect defects in the visual field only after the loss of as many as 40% of the ganglion cells. Hence, the measurement of RNFL thickness has come up. Optical coherence tomography and scanning laser polarimetry (SLP) are the techniques that utilize the evaluation of RNFL for the evaluation of glaucoma. SLP provides RNFL thickness measurements based upon the birefringence of the retinal ganglion cell axons. We have reviewed the published literature on the use of SLP in glaucoma. This review elucidates the technological principles, recent developments and the role of SLP in the diagnosis and monitoring of glaucomatous optic neuropathy, in the light of scientific evidence so far.

3.
Indian J Pathol Microbiol ; 2014 Jan-Mar 57 (1): 116-119
Article in English | IMSEAR | ID: sea-155984

ABSTRACT

Hepatoid adenocarcinoma of the stomach is a rare form of gastric carcinoma with specifi c clinicopathological features and extremely poor prognosis. Here, we report a case of a 60-year-old male patient who presented in the outpatient department with pain abdomen and constitutional symptoms. Radiological examination revealed a growth involving the antrum of the stomach while the liver and spleen were normal. The serum alpha fetoproteins were 6590 ng/ml. The patient underwent a partial gastrectomy and microscopic examination of the growth showed two types of histological patterns. Majority of the tumor displayed hepatoid differentiation with adenocarcinomatous foci. Periodic acid Schiff positive intracytoplasmic hyaline globules were seen. The tumor was immunohistochemically positive for alpha fetoprotein. The patient underwent radical gastrectomy, received chemotherapy and has been on follow-up for the past 12 months. Though known to be an aggressive neoplasm early diagnosis of hepatoid adenocarcinoma can help improve the prognosis of the disease.

SELECTION OF CITATIONS
SEARCH DETAIL